1). THE COMPRESSOR WILL NOT START:
CAUSE:
- Power failure.
- Activation of main protection and activation of motor protection.
- Temperature indicator or temperature tranducer fault.
- Temperature indicator (micro processor controller) Activated. Because temperature is too high.
- Ambient temperature too low.
SOLUTION:
- Check for supply voltage in the power supply terminals.
- Check the protection, replace or switch ON.
- Check replace if damaged.
- Check:
- remove causes of insufficient cooling.
- thermostat - if faulty to replace the entire thermostat or its cartridge.
- Heat the room upto reach atleast +5°c.
2). DIFFICULT COMPRESSORS START:
CAUSE:
- Supply voltage too low.
- Ambient temperature too low.
- Non return valve fault.
SOLUTION:
- Check supply voltage bring it to correct value.
- Heat the room upto reach atleast 5°C.
- Call the service.
3). WRONG ROTATION DIRECTION:
CAUSE:
- Wrong phase sequence.
SOLUTION:
- Swap two phase leads in the compressor terminal block or electric cabinet.
Advertisement
4). OIL TEMPERATURE TOO HIGH COMPRESSOR DOES NOT START:
CAUSE:
- Ambient temperature >40°C.
- Contaminated cooler.
- Operating pressure above the set value.
- Oil level too low.
- Oil thermostat malfunction.
- Lack of cooling water.
- Damaged temperature transducers.
- Other damage.
SOLUTION:
- Ensure adequate ventilation in the room.
- Clean the cooler (exchanger).
- Adjust the pressure switch or enter correct settings in the controller.
- Top oil up as required.
- Replace the entire thermostat or its cartridge.
- Provide water to Compressor.
- Replace with a new one.
- Call the service.
5). FORCING PRESSURE TOO LOW:
CAUSE:
- Wrong pressure switch or microprocessor controller setting.
- Insufficient Compressor capacity in relation to air requirement.
- Leak in the system.
- Air filter contaminated.
- Damaged pressure transducer.
- Damaged suction regulator.
SOLUTION:
- Adjust the pressure switch or enter the correct settings in the controller.
- Install additional source of Compressed air.
- Check the tubing for leaks, remove leaks if any.
- Change air filter cartridge (during the warranty period to be replaced obligatorily by the service staff only).
- Replace with a new one.
- Call the service staff.
6). ACTIVATION OF MOTOR PROTECTION:
CAUSE:
- Ambient temperature too high.
- Failure of one phase motor power supply.
- Supply voltage too low.
- Discharge pressure higher than specified on the name plate.
- Screw seizure.
SOLUTION:
- Improve room ventilation.
- Check motor leads, contractor and protection.
- Ensure correct supply voltage.
- Adjust the correct settings in the controller.
- Call service.
7). ACTIVATION OF SAFETY VALVE:
CAUSE:
- Safety valve damaged.
- Wrong microprocessor controller setting.
- Damaged pressure transducer.
- Damaged suction regulator.
SOLUTION:
- Replace with new one (with appropriate. setting) or call service.
- Adjust the correct settings in the controller.
- Call the service staff.
- Call the service staff.